Conformity to type with random checking is the
system whereby the manufacturer of the safety
component, employs a notified body, such as RASOO, to
ascertain and certify that the manufacturing
processes assures conformity of the safety component
with the type as described in the EC
type-examination certificate. The notified body must
carry out checks on the safety components and the
quality plans for the safety components at random
intervals. These checks are based around a core time
of one-year intervals, however this will be
dependent on changes in production levels and
previous
results of checks. This procedure is
particularly useful for those companies that do not
run a formally approved quality assurance system or
the system registration is not with a notified body.
EC TYPE-EXAMINATION OF LIFTS (ANNEX
V.B of the Directive)
EC type-examination is the procedure
whereby a notified body, ascertains and certifies
that a model lift, or a lift for which there is no
provision for an extension or variant, satisfies the
requirements of the Directive. This procedure is
conducted by examination of the technical dossier
and a representative model of the lift and to
perform or have performed the appropriate checks and
tests necessary to check that the solutions adopted
by the installer of the lift meet the requirements
of the Directive and allow the lift to comply with
them.
FINAL INSPECTION (ANNEX VI of the
Directive)
Final inspection is the procedure
whereby an installer obtains Certification from a
notified body that a lift being placed on the market
conforms with the model lift described in the EC
type-examination certificate and the EHSR?
applicable to it.
UNIT VERIFICATION (ANNEX X of the
Directive)
Unit verification is the procedure
whereby the installer of the lift obtains
Certification from a notified body that a lift that
is being placed on the market is in conformance with
the technical dossier supplied with the lift and is
in conformity with the relevant requirements of the
Directive.
PRODUCT QUALITY ASSURANCE (ANNEX XII
of the Directive)
Product quality assurance is the
procedure whereby the installer of a lift conducts
examinations and appropriate tests (final
inspection), as set out in the relevant standards,
on each lift being placed on the market. This final
inspection must be carried out under a quality
assurance system, operated under the principles of
EN 29003, this system must be assessed by a notified
body such as RASOO. The notified body will assess the
quality system by inspection of the quality
assurance system documentation, technical
documentation relevant to the lift and quality
records. Regular audits will be conducted and the
notified body may pay unexpected visits to the lift
installation sites.
FULL QUALITY ASSURANCE FOR LIFTS
(ANNEX XIII of the Directive)
Full quality assurance for lifts is
the procedure whereby the installer of the lift
operates a quality assurance system for design,
manufacture, assembly, installation, testing and
final inspection of the lifts. The quality assurance
system must be operated under the principles of EN
29001 and must be assessed by a notified body, such
as RASOO. The notified body will assess the quality
system by inspection of the quality assurance system
documentation, quality records provided for in the
design part of the quality assurance system, such as
results of analyses, calculations, tests etc., and
quality records provided for in the part of the
quality assurance system concerning acceptance of
supplies and installations, such as inspection
reports and test data, calibration data
qualifications of personnel
etc. Regular audits will be
conducted and the notified body may pay unexpected
visits to the premises of the installer and lift
installation sites.
PRODUCTION QUALITY ASSURANCE (ANNEX
XIV of the Directive)
Production quality assurance for
lifts is the procedure whereby the installer of the
lift operates a quality assurance system for
production, installation, testing and final
inspection of the lifts. The quality assurance
system must be operated under the principles of EN
29002 and must be assessed by a notified body, such
as RASOO. The notified body will assess the quality
system by inspection of the quality assurance system
documentation and the quality records, such as
inspection reports and test data, calibration data
and qualifications of personnel concerned.
电梯指令一致性评估程序
1. 电梯一致性评估程序
1)如果它是按照一台已经通过附录V所述EC型式试验的电梯进行设计的,它应在安装和测试中实施下列程序:
附录VI所提及的最终检验,或者
附录XII所提及的质量保证体系,或者
附录XIV所提及的质量保证体系。
2)如果它是按照一台已经通过附录V所述EC型式试验的电梯进行设计的,它应在安装和测试中实施下列程序:
附录VI所提及的最终检验,或者
附录XII所提及的质量保证体系,或者
附录XIV所提及的质量保证体系。
3)如果它是按照XIII实施一种质量保证体系并补充了设计审查的一台电梯进行设计,假若后者指设计审查未完全按照协调标准时,它应在安装,建造和测试中补充实施下列程序:
附录VI所述的最终检验,或者
按照附录XII的质量保证体系,或者
按照附录XIV的质量保证体系。
2. 电梯在投放市场之前必须经过下列程序中的一种:
或者,由公告机构按照附录X的规定进行的单机验证程序;
或者,如果产品未完全按照协调标准设计时,已经按照XIII的质量保证体系补充进行了一项设计审核。
3. 相关安全部件一致性评估程序
列入附录IV的安全部件投放市场之前,安全部件的制造商或其设立在欧共体的授权代表必须遵守:
具备质量控制的EC型式试验(i和ii)或全面质量保证体系;
- 或者提交按照附录V进行EC型式试验和按照附录XI公告机构进行产品审查所需的安全部件的样品;
-
或者提交按照附录V进行EC型式试验和按照附录VIII质量保证体系运行而审查产品所需要的安全部件的样品;
- 或者按照附录IX的全面质量保证体系运行;
每个安全部件上加贴CE标志并起草一份包含附录II所列资料并考虑在有关附录(附录VIII, IX 或 XI
视情况而定)中给出的技术规范的一致性声明;
从加工完成最后一批安全部件之日起应将一致性声明的副本保存10年。